363-206-285 Circuit Order: NTP-024
Issue 2, February 2000 Page 14 of 24
DDM-2000 OC-3 MULTIPLEXER
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
44.
NOTE:
Shelves that are part of a subnetwork being partitioned into
multiple areas require that the NSAPAREA field and level 2
IS-IS routing parameters of the ent-ulsdcc-l3:
command be set. See Section 11 Commands and Reports
in 363-206-285,
DDM-2000 OC-3 Multiplexer, TARP Release
13 and Later, User/Service Manual—Volume I
and
363-206-295,
DDM-2000 OC-12 Multiplexer, TARP Release
7, User/Service Manual—Volume I
, for an explanation of the
command parameters and 824-102-144,
Lucent
Technologies 2000 Product Family, Operations Interworking
Guide For TARP Releases
, for an explanation of the
engineering rules for subnetwork partitioning.
Use the ent-ulsdcc-l3: command to designate the
NSAPAREA field and level 2 IS-IS routing, as required.