363-206-285 Circuit Order: NTP-026
Issue 2, February 2000 Page 3 of 10
DDM-2000 OC-3 MULTIPLEXER
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
NOTE:
If the DDM-2000 fails to respond in the indicated manner,
refer to Trouble Clearing: IXL-001.
Use the rtrv-alm: command to verify that no alarms, locks,
loops, or switches are present.
2. Notify maintenance center that alarms will be generated.
3.
NOTE:
It may be helpful to make a sketch of the network to visualize
the cross-connections required.
Use rtrv-map-network: and rtrv-map-neighbor:
commands to determine systems (sites) in the network and how
they are connected to each other.
4.
NOTE:
Two or more shelves in the same network cannot have the
same system name or TID (set by the set-ne: command).
Verify no duplicate TID settings exist. The rtrv-ne: command
may be used at each shelf in the network to display settings. If
duplicates exist, determine new settings and use the set-ne:
command to make new settings.
5. What Release of software is installed in the system?
If Release 15 software is installed, continue with Step 6.
If Release 13 software is installed, proceed to Step 7.