363-206-285 System Turnup: NTP-033
Issue 2, February 2000 Page 6 of 6
DDM-2000 OC-3 MULTIPLEXER
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
14.
NOTE:
If a port is in the nmon (n) state, the signal is not monitored
or alarmed. The port will not automatically go to the in
service (i) state when a signal is detected as it will in the
auto (a)state.Inthenmon state, the port must be returned
to the auto state, using the set-state-t1: command, to
turn on monitoring of signal failures and before any circuit
packs associated with that port can be removed from the
equipment list by the upd command.
Use the set-state-t1: command to set the port state of the
DS1 port(s) of the circuit being established.