363-206-285 System Turnup: NTP-040
Issue 2, February 2000 Page 8 of 10
DDM-2000 OC-3 MULTIPLEXER
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
20.
NOTE:
The rtrv-pm-line command in the following procedure
displays performance monitoring data associated with the
OC-3 lines terminated on the system.
DLP-515Perform end-to-end OC-3 line test.
21. Repeat this procedure from Step 17 for all OC-3 optical spans
back to the host OC-12 shelf.
22.
NOTE:
Establishing service requires that the proper slots in each
terminating node be properly equipped with the correct
circuit pack(s) for the type of service being established. It
also requires numerous cross connections in each of the
nodes representing the path of the required service.
Additionally, transmission tests should be performed to verify
the continuity and quality of the established circuit.
The single-homed DDM-2000 OC-3 access network is now ready
for initial service to be established. For DS3, EC-1, STS-3c, and
video terminations on a DDM-2000 OC-12 shelf, use the
procedures in 363-206-295,
DDM-2000 OC-12 Multiplexer, TARP
Release 7, User/Service Manual (TOP)Volume II
to establish
those services. For DS1, DS3, and/or EC-1 terminations on a
DDM-2000 OC-3 shelf, use the procedures in this 363-206-285,
DDM-2000 OC-3 Multiplexer, TARP Release 13 and Later,
User/Service Manual (TOP)Volume II
to establish those
services.