363-206-285 Circuit Order: NTP-049
Issue 2, February 2000 Page 1 of 10
DDM-2000 OC-3 MULTIPLEXER
Establish OC-3 Optical Span
Between FT-2000 Ring and DDM-2000 OC-3 or OC-12
Ring
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
1.
!
CAUTION:
DDM-2000 circuit packs contain static sensitive components
which can be damaged by electrostatic discharge. A static
ground wrist strap must be worn when handling the circuit
packs. See electrostatic discharge considerations in
Trouble
Clearing: TAD-100
.
NOTE:
This procedure assumes that the FT-2000 OC-48 ring is in
service and a new OC-3 optical span is being added
between the OC-48 ring and DDM-2000 OC-3 or OC-12
ring. See Figure 1.
NOTE:
If the DDM-2000 fails to respond in the indicated manner,
refer to Trouble Clearing: IXL-001.
Use rtrv-alm: command to verify that no alarms, locks, loops,
or switches are present.
2. Notify maintenance center that alarms will be generated.
TAD-100

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals