363-206-285 Circuit Order: NTP-052
Issue 2, February 2000 Page 2 of 6
DDM-2000 OC-3 MULTIPLEXER
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
3.
NOTE:
The UPD/INIT pushbutton on the SYSCTL is recessed to
prevent its accidental operation. You will need a small
pointed object such as a ball-point pen to operate it.
Momentarily depress the UPD/INIT buttonontheSYSCTL at the
T1 terminating nodes or use the upd command to update the
equipment list. (Flashing FAULT LEDs go off.)
4. If a craft interface terminal (CIT) is available, use the
rtrv-state-eqpt: command to verify that the right port has
been changed from in-service (i)toauto (a)state.
5.
!
CAUTION:
Removing the wrong cross-connection may cause service
interruption. Use the
rtrv-crs-( )
command to determine
the proper cross-connections.
From work order or rtrv-crs-( ) command, determine the
cross-connections for circuit being discontinued.

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals