NTP-054: System Turnup 363-206-285
Page 9 of 14 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
19. Repeat this procedure from Step 14 for all OC-3 optical spans
being established in the DDM-2000 OC-12/OC-3 network. Ensure
that the last optical span connected to the OC-12 host shelf is
connected to an OLIU in the opposite slot as the one in the first
host OC-12 (for example in Figure 3, slot 1 at one host node and
slot 2(P) at the other host node).
20.
NOTE:
Establishing service requires that the proper slots in each
terminating node be properly equipped with the correct
circuit pack(s) for the type of service being established. It
also requires numerous cross connections in each of the
nodes representing the path of the required service.
Additionally, transmission tests should be performed to verify
the continuity and quality of the established circuit.
The single-homed DDM-2000 OC-3 access network is now ready
for initial service to be established. For DS1, DS3, EC-1, STS-3c,
T1, HDSL, and/or LAN terminations on a DDM-2000 OC-3 shelf,
use the procedures in this 363-206-285,
DDM-2000 OC-3
Multiplexer, TARP Release 13 and Later, User/Service Manual
(TOP)—Volume II
to establish those services.

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals