TAP-101 : Trouble Clearing 363-206-285
Page 1 of 10 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
Clear Critical (CR) Alarm
1.
NOTE:
Critical alarms are failures that cause loss of service to more than four
DS1s (96 DS0 customer channels). Table A lists conditions which may
cause critical alarms.
Connect the CIT to the CIT connector on the near-end User Panel and log in to
the near-end system, if not already performed.
Reference: DLP-521
2.
NOTE:
The rtrv-alm: command can be used to display a report of active
DDM-2000 OC-3 alarm and status conditions. The Commands and
Reports section of this manual gives a description of the command.
NOTE:
The Active Alarm and Status Report is output automatically
following CIT log in. The report shown in Figure 1 is an example that
shows several entries. There may be only one entry in the actual report.
Note the information in the Source Address and Description columns for
the top entry/entries above the first single-dashed line in the Active Alarm
and Status Report (for example, CRITICAL ... inc. OC3 LOS in the report
below).
DLP-521

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals