363-206-285 Trouble Clearing: TAP-102
Issue 2, February 2000 Page 2 of 14
DDM-2000 OC-3 MULTIPLEXER
3.
NOTE:
Local alarm or status conditions have a Source Address of the local
slot, line, port, channel, path, cross-connection, or operations interface
(DCC, X.25, etc.) where the event occurred. (See
Addresses
in the
Commands and Reports section of this manual.) Use the rtrv-alm:
command to get another report, if necessary.
Note the local trouble indication in the Description column of the Active
Alarm and Status Report, starting with the highest alarm level (Major)
listed in the Alarm Level column.
4. Use opr-aco; command to silence active audible office alarms, if required.
5. See Table A for trouble description for the highest alarm level and go to the
indicated step or procedure.