363-206-285 Trouble Clearing: TAP-102
Issue 2, February 2000 Page 12 of 14
DDM-2000 OC-3 MULTIPLEXER
42.
NOTE:
A major alarm may also be caused by a wrong circuit pack inserted into
the AUXCTL slot, DS1 line code switch settings that are different from
what they were before a DS1/DS1PM circuit pack was replaced,
excessive holdover due to loss of synchronization reference, or a manual
switch to holdover in effect too long.
Is any circuit pack except an OHCTL installed in the AUXCTL slot?
If YES, then continue with Step 43.
If NO, then proceed to Step 45.
43. Remove wrong circuit pack from AUXCTL slot and install correct OHCTL
circuit pack [DLP-523].
44. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
45.
!
CAUTION:
If a DS1 is switched to protection, removal of any other
DS1/DS1PM
circuit pack or
177P
Retainer Card in the same group will result in a loss
of service to the protected DS1 and the removed
DS1/DS1PM
circuit
pack.
Has an unprotected DS1/DS1PM circuit pack or more than one DS1/DS1PM
circuit pack been removed from the system?
If YES, then continue with Step 46.
If NO, then proceed to Step 48.
46. Determine the reason the circuit packs were removed. If the same circuit
pack(s) is to be reinserted and no switch settings are changed, reinstall the
circuit pack. If the circuit pack was removed and switch settings changed,
reinstall the circuit pack and momentarily depress the UPD/INIT buttononthe
SYSCTL. If the circuit pack is not to be reinserted, momentarily depress the
UPD/INIT button on the SYSCTL to remove the circuit pack from the inventory.
47. STOP. YOU HAVE COMPLETED THIS PROCEDURE.

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals