363-206-285 Trouble Clearing: TAP-111
Issue 2, February 2000 Page 6 of 6
DDM-2000 OC-3 MULTIPLEXER
29. Is FAULT LED(s) lighted or flashing?
If FLASHING, then continue with Step 30.
If LIGHTED, then do TAP-106.
30. Trouble is in optical fiber. Clear trouble using local procedures.
31. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
32. Multiple troubles exist which are beyond the scope of this document. Without
knowing the exact LED indications, the alarm and status indications (obtained
with the rtrv-alm: command), or the state of the protection switch (using the
rtrv-state-eqpt: command), this procedure can not go any further.
Use the LED indications, the rtrv-alm: and rtrv-state-eqpt:
commands to analyze the trouble. Look for protection switch locks or inhibits. If
the system is found to be completely out of service, replace circuit packs with
lighted FAULT LEDs. If system is still in-service and a protection switch can
placeallserviceoneithertheprotectionorserviceOLIUs, perform the switch
then replace circuit packs with lighted FAULT LEDs.
If you need technical assistance, notify your supervisor, your local technical
support organization, or call Lucent Technologies RTAC, per local operating
instructions.
33. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
TAP-106

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals