363-206-285 Trouble Clearing: TAP-116
Issue 2, February 2000 Page 1 of 6
DDM-2000 OC-3 MULTIPLEXER
Clear Trouble During Network Element
Program Upgrade
1.
NOTE:
Program installation may fail due to failure of communication link between
PC and DDM-2000, failure of the floppy disk or hard disk on the PC,
failure or loss of power in the PC, or failure of the SYSCTL or OHCTL.
See ins-prog: and cpy-prog: command pages in the Commands
and Reports section of Volume 1 of this manual for other failure
indications.
Was the following message received?
SCSN
/* Status, invalid Command SequeNce. */
/* Incompatible software.*/
If YES, then continue with Step 2.
If NO, then proceed to Step 4.
2. Indications are that you are trying to download software that is incompatible
with the shelf type (for example, DDM-2000 OC-12 software into a DDM-2000
OC-3 shelf) or Controller type (for example, ring software prior to Release 9
into BBG8/BBG8B and BBG9 controllers. Find compatible software.
If you need assistance, notify your supervisor, your local technical support
organization, or call Lucent Technologies RTAC, per local operating
instructions.
3. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
4. Was the following message received?
/* Status, execution stopped. */
/* Communication link could not be established.
Please connect PC with program to be installed and start
again. */
If YES, then continue with Step 5.
If NO, then proceed to Step 6.