363-206-285 Trouble Clearing: TAP-116
Issue 2, February 2000 Page 3 of 6
DDM-2000 OC-3 MULTIPLEXER
12. Did SYSCTL or OHCTL fail, indicated by the following or similar SYSCTL CP
failed message?
ins-prog:tid DENY
SSTP
/*Status, execution stopped.*/
/*Installation cannot be done because of SYSCTL test
failure. */
If YES, then proceed to Step 17.
If NO, then continue with Step 13.
13. Did FAULT LED on SYSCTL light and did the SYSCTL FE ID display go off?
If YES, then proceed to Step 19.
If NO, then continue with Step 14.
14.
NOTE:
It is assumed that the program installation failed in one of two ways:
before the old program was erased or after the old program was erased.
If the program installation failed after 1 minute, the DDM-2000 may have
erased its old program and will be unable to report alarms or do
protection switches. If program installation failed within 1 minute, the old
program may not have been erased and the DDM-2000 may have
automatically reset and restarted its old program. A new attempt must be
made to install the program.
Check PC COM( ) port to CIT connection. Check PC disk drive and floppy
diskette.

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals