DLP-512: Detailed Level Procedure 363-206-285
Page 10 of 10 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
Enhanced DS3
Path for P-Bits,
F&M-Bits,
and C-Bits from
Fiber and DSX
CV-P Coding Violations
ES-P Errored Seconds
SES-P Severely Errored Seconds
UAS-P Unavailable Seconds
SEFS
1-16383[40]
1-900[25]
1-63[4]
1-63[10]
1-63[2]
1-1048575[3820]
1-65535[250]
1-4095[40]
1-4095[10]
1-4095[8]
t3
t3
t3
t3
t3
DS3 Line CV-L Coding Violations
Errored Seconds, Line (ES-L)
Severely Errored Seconds, Line (SES-L)
1-16383[40]
1-900[25]
1-63[4]
1-1048575[3865]
1-65535[250]
1-4095[40]
t3
t3
t3
VT1.5 Path V5 Errored Seconds (ES)
V5 Severely Errored Seconds (SES)
V5 Unavailable Seconds (UAS)
1-900 [40]
1-63[20]
1-63[30]
1-65535 [900]
1-4095 [60]
1-4095 [90]
vtl
vtl
vtl
DS1 Path ES-P Errored Seconds
SES-P Severely Errored Seconds
UAS-P Unavailable Seconds
ES-PFE Errored Seconds
SES-PFE Severely Errored Seconds
UAS-PFE Unavailable Seconds
CV-P (SF) Coding Violations
CV-P (ESF) Coding Violations
CV-PFE Coding Violations
1-900[65]
1-63[10]
1-63[10]
1-900[65]
1-63[10]
1-63[10]
1-16383[72]
1-16383[13296]
1-16383[13296]
1-65535 [648]
1-4095 [100]
1-4095 [10]
1-65535 [648]
1-4095 [100]
1-4095 [10]
1-1048575 [691]
1-1048575 [132960]
1-1048575 [132960]
tl
t1
t1
t1
t1
t1
t1
t1
t1
DS1 Line ES-L Line Errored Seconds 1-900[65] 1-65535 [648] tl
* Threshold is set once for both current quarter hour and current day.
†Applicable only when using the 24G-U/24H-U or 29G-U/29H-U OLIU in MAIN slots.
Table B – DDM-2000 OC-3 Performance Monitoring Parameters Provisionable Via the
CIT (Contd)
Parameter Definition Threshold Range [Default] Command
Facility Measure
Current
Quarter Hour
Current
Day set-pmthres-