DLP-546: Detailed Level Procedure 363-206-285
Page 1 of 20 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
Make VT1.5 (DS1) or STS1 (DS3) Cross-Connections
Using CIT Single OC-3 or OC-12 Ring Configuration
1.
NOTE:
If you are not familiar with doing cross-connections using the CIT
commands, it is strongly suggested that you read Cross-Connection
Provisioning in the Administration and Provisioning section of this
manual. Also, read the description of the following commands in the
Commands and Reports section of this manual: ent-crs-sts1,
ent-crs-vt1, rtrv-crs-sts1, rtrv-crs-vt1, dlt-crs-sts1,
dlt-crs-vt1, and cnvt-crs.
NOTE:
You may have to log in to more than one node to get a complete map of
the network using the rtrv-map-network and rtrv-map-neighbor
command. If a drawing of the network is not provided with the work order,
it is recommended that you draw a simple schematic of the network
before making cross-connections. List the TID of each node and how
they are connected to each other. Figure 1 shows an example of a simple
schematic.