DLP-546: Detailed Level Procedure 363-206-285
Page 7 of 20 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
10. Use the rtrv-crs-vt1: or rtrv-crs-sts1: command to verify that the
proper connection has been made. If an improper cross-connection is made,
use the dlt-crs-vt1: or dlt-crs-sts1: command to delete the improper
cross-connection and reenter the cross-connection.
11. After all cross-connections are made, use the rtrv-alm: command to verify
no alarms are present.
12. If DS3 cross-connections have been established and the terminating nodes
are equipped with BBG4B DS3 circuit packs, use set-trace-sts1
command to check integrity of cross-connect path.
Reference: DLP-563
13. If ne-acty inc. VT AIS, inc. STS1 AIS, inc. VT unequipped,or
inc. STS1 unequipped, alarms are present, look for missing or improperly
made cross-connections. Use TAP-120 to locate missing cross-connections, if
required.
14. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
DLP-563
TAP-120