DLP-550: Detailed Level Procedure 363-206-285
Page 4 of 12 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
Figure 3 – Sample Report From rtrv-map-neighbor Command (R13)
Figure 4 – Sample Report From rtrv-map-neighbor Command (R15)
2. Verify system configuration is same as specified on work order or circuit order.
3. From work order or circuit order, determine the terminating (drop) nodes for
the service being established.
/* Neighbor Map for Site6NE1
=================================================================
TID Connected Thru Product Type Level 2 IS
NSAP
=================================================================
Site6NE1 DDM-2000 OC-3
39 840F 80 000000 0000 0000 0000 08006alad06e 00
Site7NE1 main-1 Y
39 840F 80 000000 0000 0000 0000 08006alad06f 00
Site5NE1 main-2
39 840F 80 000000 0000 0000 0000 00000e3a0372 00
*/
/* Neighbor Map for Site6NE1
=================================================================
TID Connected Thru Product Type Level 2 IS DCC
NSAP
=================================================================
Site6NE1 DDM-2000 OC-3 Y
39 840F 80 000000 0000 0000 0000 08006alad06e 00
Site7NE1 main-1 N
39 840F 80 000000 0000 0000 0000 08006alad06f 00
Site5NE1 main-2
39 840F 80 000000 0000 0000 0000 00000e3a0372 00
*/

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals