363-206-285 Detailed Level Procedure: DLP-560
Issue 2, February 2000 Page 1 of 18
DDM-2000 OC-3 MULTIPLEXER
Make Cross-Connections Using CIT
Single/Dual Homing OC-12/OC-3 Ring Configuration
1.
NOTE:
If you are not familiar with doing cross-connections using the CIT
commands, it is strongly suggested that you read Cross-Connection
Provisioning in the Administration and Provisioning section of this
manual. Also, read the description of the following commands in the
Commands and Reports section of this manual and the DDM-2000 OC-3
manual: ent-crs-sts1, ent-crs-vt1 (OC-3 only), rtrv-crs-sts1,
rtrv-crs-vt1 (OC-3 only), dlt-crs-sts1, and dlt-crs-vt1
(OC-3 only).
NOTE:
You will have to login to more than one node in each ring to get a
complete map of the network using the rtrv-map-network: and
rtrv-map-neighbor: command. If a drawing of the network is not
provided with the work order, it is recommended that you draw a simple
schematic of the network before making cross-connections.
Make a simple drawing of the network and list the TID of each node and
how they are connected to each other. Figures 1 thru 4 show examples of
simple schematics.