363-206-285 Detailed Level Procedure: DLP-563
Issue 2, February 2000 Page 3 of 4
DDM-2000 OC-3 MULTIPLEXER
13. Indications are that the Incoming Path Trace string message (INCTRC) does
not match the Expected Path Trace string message (EXPTRC)—(Status:
MISMATCH). Verify that the path string entered as the Expected Incoming Path
Trace (EXPTRC) at this node matches exactly the Outgoing Path Trace string
(TRC) entered at the other terminating node. circuit packs. Verify
cross-connections and terminating addresses at all nodes. Repeat this test
from Step 9.
14. Has the rtrv-trace-sts1:address command been performed at both
terminating ends?
If YES, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then continue with Step 15.
15. Log out of remote location. Repeat this test from Step 9. for the other
terminating end.