363-206-285
Circuit Pack Descriptions
Issue 3 June 2001
7-149
Control Functions 7
The major control functions are as follows:
■ Switches protection for OC-1 line and STS1E, MXRVO, other OLIU, and
TG circuit packs
■ Processes transport and path overhead
■ Stores inventory information (
CLEI
code, date of manufacture, etc.)
■ Supports VT, STS, and OC-1 signal degrade protection switching
■ Supports STS-1 BER signal fail (10
-3
or 10
-6
) path protection switching
■ Supports path protection switching based on STS-1 unequipped, STS-1
AIS, STS-1 LOP, VT AIS, VT unequipped, and VT LOP.
Maintenance Signal Functions 7
The major maintenance signal functions are as follows:
■ Inserts and detects STS-1 path AIS or inserts and detects VT1.5 path AIS
■ Inserts and detects OC-1 line AIS
■ Inserts and detects STS-1 path unequipped signal
■ Inserts and detects VT path unequipped signal
■ Inserts and detects line FERF
■ Inserts and detects STS-1 path yellow, if VT1.5 cross-connected
■ Detects OC-1 line failures (LOS, LOF, AIS, and BER)
■ Detects OC-1 line signal degrade BER.