363-206-285
System Introduction
1-18 Issue 3 June 2001
— Alarm severity escalation. Allows the user to provision (enable/
disable) the alarming of service affecting/non-service affecting
entities.
— CPro-2000, ITM SNC support. Release 13.0 is supported by:
CPro-2000 Release 7.0; ITM SNC Release 5.0 (supports enhanced
database backup and restore capabilities).
— Reports all active users through the DCC and X.25.
— Default TID. The default Target Identifier (TID) for R13.0 is LT-DDM-
2000, instead of the previous default of Site#NE#.
— TL1 commands:
— RTRV-CID-SECU (also new CIT command RTRV-SECU) to
report the active user logins.
— RTRV-LOG to report the 500 most recent events in the
history log (equivalent to existing CIT command RTRV-
HSTY).
— ENT-FECOM to provision DCC user-side/network-side
settings and to enable or disable remote access via each
DCC (equivalent to existing CIT command SET-FECOM
which is now supported via CIT remote login and OS).
— RTRV-FECOM to report the provisioned state of each DCC
(equivalent to existing CIT command RTRV-FECOM).
Release 15.0 is an enhanced ring release which provides all the transmission
features of Release 13.0. In addition, Release 15.0 supports the following
applications and features:
â– New Applications:
— IMA LAN Interface. With the introduction of a new low-speed circuit
pack, Release 15.0 provides a direct IMA LAN to WAN interface
through the DDM-2000 OC-3.
â– The IMA LAN (BBF9 metallic or BBF10 optical) circuit pack
provides an interface for one 10/100BaseT, 100BaseFX IEEE
802.3 standard compliant interface.
— T1 Interface. The T1EXT (BBF6) circuit pack provides line
termination for two bi-directional T1 line interfaces. Signals received
from the T1 interface are mapped into SONET VT1.5 signals. The
resulting signals are routed to the OLIU circuit packs. The T1EXT
circuit pack is used only with the enhanced MXRVO (BBG2B) circuit
pack in Groups 3 and 4 shelves. This can also be used in Group 3
shelves per C8854. Requires separate secondary lightning and
surge protection in outside plant applications.