Malfunctions during crane operation
14.5 Emergency operations and programs
14 - 48 3 112 xxx en Operating Manual GMK6300L
xx.xx.xxxx
• Open the main menu ö and press the button (1) once.
The
Telescoping submenu opens.
The emergency program is active if:
– The symbol (2) is displayed
– The display (1) is shown for approx.
360 seconds.
Within this time, the telescoping mechanism
can be operated using the emergency pro-
gram.
After this time has elapsed, the symbol (3)
appears and you need to restart the emer-
gency programme.
Determining the
type of error
• Check which emergency program procedure is suitable for the current
error:
G
Risk of damage to the telescoping mechanism!
Ensure that you always have an overview of the current status of the tele-
scoping mechanism before you initiate locking or unlocking.
In emergency mode, there is no monitoring of prerequisites – the function
is performed immediately after pressing the button.