110 Panel Functions
_________________________________________________________________________________________
_________________________________________________________________________________________
Microplex logiJET TC8 Edition 1.2
7. Measurement of Label Length
Use the panel function
logiJET TC8 \ Paper Menu \ Paper Size \ Paper Length \ Measure Length
The printer performs a material feed and reports the measured label length
on the display.
Use the ENTER key to confirm this value (configuration of the measured label
length).
In addition this new value can be saved permanent as setup value (using the
ENTER key, again).
7.5.2. Configuration of Semiautomatic Label Length Measurement
The panel function
logiJET TC8 \ Paper Menu \ Paper Size \ Paper Length \ Auto.Measurement
serves to switch the semiautomatic label length measurement function to on
or off (and to save this setting as setup value).
If the semiautomatic label length measurement function is chosen, the
printer automatically offers you the measurement of the label length after
every printer power on and after every closing of the printhead (for
example after the inserting of a new label roll):
Panel display [Measure length ]
Use the ENTER key to start the measurement of label length, use the FEED
key to suppress this function.
The printer saves the measured label length temporary (as long as the
printer stays turned on).