9.3. Incorrect Media Transport
Defect
Remedies
Incorrect media transport
(no gap detection between
labels e.g.)
- perform the basic operations
(see chapter 4)
- check if the Sync Sensor has been adjusted
correctly (see section 7.2)
- Adjust the position of the sensors (reflective
sensor and transparent sensor) suitable to your
consumables.
- check if the media has been loaded
correctly
(compare section 5.1)
- check if the ribbons have been loaded
correctly
(compare section 5.2)
- clean the sensors
(see section 8.1.4)
- check if the jammed consumables have
been removed completely.
No straight transport of the
consumables
(torsion or folding of the
ribbon, e.g.)
- check if the ribbons have been loaded
correctly (compare section 5.2)
- check if the media has been loaded
correctly
(compare section 5.1)
- check both print units: is the ribbon tension on
either side of the ribbon even? If not, adjust the
ribbon tension on either side of the ribbon.
(See section 8.2 Avoiding Ribbon Slack and
Wrinkles)
- check the printhead pressure of both printheads
(see section 5.3 Printhead Pressure Adjusting).
- clean the platen rollers
(see section 8.1.3)

Table of Contents