⑪ SPAN calibration by weight
The load cell outptu value is registered as a SPAN by writing the data in the table below.
When the data other than [0] are written in the general data area, the signal becomes an
error outside a set range. (Error code : 99, Error assistance code : 1)
Command No.
(RWwnE) : 4 stations are occupied.
(RWwn6) : 2 stations are occupied.
General data area
(RWwnC~RWwnD)
(RWwn4~RWwn5)
9010
0
SP-L error
When the read load cell output value is below than 0 mV/V and exceeds over SPAN
adjustment range at minus side, the following code is set.
Condition Error code Error assistance code
SP-L error 4 2
SP-H error
When the read load cell output value is over than 3.1 mV/V and exceeds over SPAN
adjustment range at plus side, the following code is set.
Condition Error code Error assistance code
SP-H error 4 3
Error that cannot be executed
The following code is set when executing by other than the calibration mode, or not setting it
according to the flow chart in [14-6.].
Condition Error code Error assistance code
Error that cannot be executed. 99 2
⑫ SPAN calibration by numeric input
SPAN is registered by setting the numeric value with the unit of mV/V after writing the data in
the table below.
Command No.
(RWwnE) : 4 stations are occupied.
(RWwn6) : 2 stations are occupied.
General data area
(RWwnC~RWwnD)
(RWwn4~RWwn5)
9011
Setting range : 1 ~ 31 000
SP-L error
When the read load cell output value is below than 0 mV/V and exceeds over SPAN
adjustment range at minus side, the following code is set.
Condition Error code Error assistance code
SP-L error 4 2
106
CC-Link