EasyManua.ls Logo

MR ETOS ED - Undertaking and Confirming Maintenance

MR ETOS ED
406 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 Visualization
Maschinenfabrik Reinhausen GmbH 2020300 6385142/08 ENETOS
®
ED
9.31.3 Undertaking and confirming maintenance
Once you have undertaken maintenance, you can confirm this on the device
and thereby reset the maintenance interval. The following maintenance pa-
rameters can be entered based on the maintenance type:
Value Description
Date Date of maintenance.
Operations counter Reading of the operations counter at the time of mainte-
nance.
You can enter the current counter reading or a smaller
counter reading.
Contact wear (only
OILTAP®)
MSCA
MSCB
TC1A
TC1B
TC2A
TC2B
Overall contact wear on the stationary contact and moving
contact.
If you have measured the contact wear during mainte-
nance and continue to use the contacts in their original
positions, then enter the measured values and select "No"
in the prompt that reads "Contacts exchanged/replaced"
to confirm it. This causes the monitoring system to opti-
mize its calculation model and subsequent calculation of
the contact wear is more precise.
If you have exchanged (other position) or replaced con-
tacts, then enter the contact wear found on the mounted
contacts (for new contacts: 0.000mm) and select "Yes" in
the prompt that reads "Contacts exchanged/replaced" to
confirm it.
Table92: Maintenance parameters

Table of Contents