the rack by loosening the mounting bolts of the transmission or gearbox and pushing the assembly up. The
tabletop bolts should be checked to ensure they are all tight. Filters in the electrical cabinet should be cleaned.
Bi-Annually
The electrical cabinet should be checked during the bi-annual maintenance performed on the
MultiCam
CNC machine. Operators should turn off the power before opening the cabinet and then vacuum out any
debris that may have entered the cabinet during regular working conditions. Operators should not use
compressed air when cleaning out the cabinet as this action may cause unwanted particles to short out some of
the electrical components.
MultiCam
recommends that the belts on all transmissions and Lead Screw Z-nuts be replaced every other
year.
(t) The specifications of spare parts to be used that may affect the health and safety of operators are attached.
(u) The information on airborne noise emissions is attached.
(v) The machinery is likely to emit non-ionizing radiation that may cause harm to persons, in particular persons
with active or non-active implantable medical devices, in these places. The information regarding the radiation
emitted for the operator and exposed persons is attached.