EasyManua.ls Logo

NEC SL1100 - Page 795

NEC SL1100
864 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program Num-
ber
Program Name Default
45-05-08 Voice Mail Send Protocol Signal Without Additional Dig-
its - Conversation Recording
0
45-05-09 Voice Mail Send Protocol Signal Without Additional Dig-
its - Clear Down String
0
80-03-01 DTMF Tone Receiver Setup - Detect Level Type 1~5 = 0
80-03-02 DTMF Tone Receiver Setup - Start delay time Type 1~5 = 0
80-03-03 DTMF Tone Receiver Setup - Min. detect level Type 1 = 10 (-20dBm)
Type 2 = 15 (-25dBm)
Type 3 = 15 (-25dBm)
Type 4 = 10 (-20dBm)
Type 5 = 10 (-20dBm)
80-03-04 DTMF Tone Receiver Setup - Max. detect level 2 (-2dBm)
80-03-05 DTMF Tone Receiver Setup - Forward twist level Type 1~5 = 5 (6dBm)
80-03-06 DTMF Tone Receiver Setup - Backward twist level Type 1~5 = 0 (1dBm)
80-03-07 DTMF Tone Receiver Setup - ON detect time Type 1~5 = 1 (30ms)
80-03-08 DTMF Tone Receiver Setup - OFF detect time Type 1~5 = 1 (30ms)
80-04-01 Call Progress Tone Detector Setup - Detection Level Type 1 (DT) = 0 (-25dBm)
Type 2 (BT) = 0 (-25dBm)
Type 3 (RBT) = 0 (-25dBm)
Type 4 = 0
Type 5 = 0
80-04-02 Call Progress Tone Detector Setup - Min. Detection Lev-
el
0~15
Type 1 (DT) = 15 (-25dBm)
Type 2 (BT) = 15 (-25dBm)
Type 3 (RBT) = 15 (-25dBm)
Type 4 = 0
Type 5 = 0
80-04-03 Call Progress Tone Detector Setup - S/N Ratio Type 1 (DT) = 4 (-20dB)
Type 2 (BT) = 4 (-20dB)
Type 3 (RBT) = 4 (-20dB)
Type 4 = 0
Type 5 = 0
80-04-04 Call Progress Tone Detector Setup - No Tone Time Type 1 (DT) = 132 (3990ms)
Type 2 (BT) = 132 (3990ms)
Type 3 (RBT) = 132 (3990ms)
Type 4 = 0
Type 5 = 0
80-04-05 Call Progress Tone Detector Setup - Pulse Count Type 1 (DT) = 1
Type 2 (BT) = 1
Type 3 (RBT) = 1
Type 4 = 0
Type 5 = 0
80-04-06 Call Progress Tone Detector Setup - ON minimum time Type 1 (DT) = 9 (300ms)
Type 2 (BT) = 12 (390ms)
Type 3 (RBT) = 25 (780ms)
Type 4 = 0
Type 5 = 0
80-04-07 Call Progress Tone Detector Setup - ON maximum time Type 1 (DT) = 0
Type 2 (BT) = 14 (450ms)
Type 3 (RBT) = 40 1230ms)
Type 4 = 0
Type 5 = 0
80-04-08 Call Progress Tone Detector Setup - OFF minimum time Type 1 (DT) = 1 (60ms)
Type 2 (BT) = 10 (330ms)
Type 3 (RBT) = 83 (2520ms)
Type 4 = 0
Type 5 = 0
ISSUE 2.0 SL1100
Features and Specifications Manual 1-783
V

Table of Contents

Other manuals for NEC SL1100

Related product manuals