Error Messages 10
Pulse Laser Station NPL-302 Series Instruction Manual 211
NO Stn Setup 108.5
There is no station record in the current job, or a station setup or BS check has not
been done since the program was rebooted.
OVER RANGE 108.6
You are trying to record a coordinate with more than 13 digits
Press any key to return to the previous screen. Then check the current ST
coordinate.
Reflectorless Mode Measurement 10.9
Signal High% 109.1
Excessive signal is received for the Reflectorless mode measurement.
Press
[Esc] and change Reflectorless mode (Target=N-Prism) to Prism mode
(Target=Prism) by holding down the
[MSR1] or [MSR2] key for one second,
Searching 10.10
PT Not Found 1010.1
There is no point that matches the criteria you entered.
Press any key to return to the point input screen.
This message may appear in any function where the PT/CD is input, such as Station
Setup or Stakeout.
To ... Press ...
continue recording [1] or select
Continue. If there is already
an ST record in the job, the message
CO,
Use current orientation
appears.
go to the Stn Setup menu [2] or select
STN Setup
return to the previous screen [ESC]