2 Preparation
12 Pulse Laser Station NPL-302 Series Instruction Manual
To prevent malfunction, keep the charging plug clean.
If the CHARGE indicator blinks repeatedly after charging starts, there is a
problem with the battery pack. Do not use or charge the battery pack any further,
and contact your dealer.
If the ambient temperature drops below 0 °C (32 °F) while the battery pack is
charging, the charger stops charging the battery pack. When the ambient
temperature rises above 0 °C (32 °F), charging resumes. Charging will be
completed after restarting.
If the CHARGE indicator remains lit for more than four hours, and the ambient
temperature during charging was within the specified operational range
(0 °C through 40 °C or 32 °F through 104 °F), there is a problem with the
battery pack. Do not use or charge the battery pack any further, and contact your
dealer.
During charging or discharging, the battery pack and quick charger will become
warm. This is normal.
After charging the battery pack, do not recharge it until it has been fully
discharged. Recharging a fully charged battery pack lowers its performance.
If the battery pack is used at low temperatures (below –20 °C or –4 °F), its
capacity is reduced, and it will allow less operation time than a battery pack
used at normal (room) temperature.
If a battery pack is not used for a long period, it cannot be charged to its full
capacity again. To improve the battery pack’s capacity, charge and discharge it
several times.
You can use a battery charger with part number Q-70U/E or Q-70C to charge a
battery pack with part number BC-65. However, these chargers cannot fully
charge this battery pack.
Charging the battery pack
1.
Connect the power plug on the charger to
an AC power outlet.
2. Connect the charging plug on the charger
cable to the charging connector on the
battery pack.
The CHARGE indicator lights up, and
charging starts automatically.
When the battery pack is fully charged, the
CHARGE indicator turns off.
Air holes
To AC outlet
CHARGE
indicator
DISCHARGE
indicator
DISCHARGE
button