EasyManua.ls Logo

Nordson Asymtek Spectrum Series - Table 6-2 Dispensing Head Position Controls: Jog Distance and Velocity

Nordson Asymtek Spectrum Series
238 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-12 Operation
Item Description
1 Target Box
2 Y-axis Controls (forward and back movement)
3 X-axis Controls (side to side movement)
4 Radio Button (Dispenser selected)
5 Z-axis Controls (up and down movement)
Figure 6-11 Dispensing Head Position Controls
" NOTE The single arrows and double arrows
move the dispensing head different
distances and different velocities per mouse click. See
Table 6-2.
Table 6-2 Dispensing Head Position Controls: Jog Distance and Velocity
(1)
Distance
mm (inch)
(2)
Velocity
mm/sec (in/sec)
Movement
Axis
X-Y 0.0254 (0.001) 2.54 (0.100) 2.54 (0.100) 88.9 (3.500)
Z 0.0254 (0.001) 1.27 (0.050) 2.54 (0.100) 10.16 (0.400)
Notes: (1) Default distances and velocities. Refer to the Fluidmove User Guide or Online
Help to modify jog distances and velocities.
(2) Distance per mouse click on the arrow button.
1
2
3
4
5

Table of Contents