26 Chapter 3 Troubleshooting your CallPilot system
Number
of beeps Error message Error message and conditions
10
Shutdown register
error
Shutdown register read/write error has
occurred.
11
Invalid BIOS General BIOS error has occurred.
Bootblock error 3-beep codes
Number
of beeps POST code Expansion card/controller
3
00h No memory was found in the system.
3
01h Memory of mixed types was detected.
3
02h EDO is not supported.
3
03h First row memory test has failed.
3
04h Mismatched DIMMs are in a row.
3
05h Base memory test failed
3
06h Decompressing post module failed.
3
07-0Dh Generic memory error has occurred.
3
0Eh SMBus protocol error has occurred.
3
0Fh Generic memory error has occurred.
3
DDh CPU microcode cannot be found for
processor in slot 0.
3
EEh CPU microcode cannot be found for
processor in slot 1.
SCSI controller diagnostics
BIOS initialization
Most information about SCSI is displayed as part of the BIOS initialization
screen.
During BIOS initialization, check to make sure that the tape drive is listed
correctly. If the tape drive is not listed correctly:
•
Ensure that internal cable connections are made properly.
•
Check that tape drive settings are correct.
•
Check tape drive termination.
For more information refer to:
•
"SCSI and IDE drive cabling" (page 101)
•
"Replacing the tape drive" (page 109)