102 Chapter 9 Replacing media drives
SCSI and IDE drive cabling.
Replacing a faulty hard drive
If you need to replace a faulty hard drive, then do the following:
Step Action
1
Review this entire section before proceeding to become familiar with
the requirements and process.
2
Prepare the server for hard drive replacement as described in
"Preparing the server for hardware maintenance" (page 81).
ATTENTION
Due to the confined space for media drive cabling inside the server,
hard drive replacement is easiest when the server is laying on its side.
Laying the server on its side helps to prevent damage to the server and
internal components.
3
Remove the faulty drive as described in "To remove a hard drive
from the server" (page 105).
ATTENTION
Replacement drives must be the same size or larger than the drives
being replaced.
Nortel CallPilot
703t Server Maintenance and Diagnostics
NN44200-702 01.03 Standard
5.0 3 April 2007