98 Chapter 8 Replacing basic chassis components
Note: The fan closest to the top of the server connects to the
connector labeled sysfan1. The fan closest to the bottom of the
server connects to the connector that is labeled sysfan2.
8
Wrap excess cable length with a twist tie or cable wrap, and ensure
that it is placed away from the fans.
CAUTION
If a cable is caught in a fan, the fan will break.
9 Replace the server side cover.
10
Reconnect all peripheral device cables and power cord.
11
Power up the server.
—End—
Replacing the processor fan
Replace a malfunctioning fan with the same type as the one removed.
For more information about replacing a fan, contact your Nortel customer
service representative.
To remove the processor fan
CAUTION
Use an ESD wrist strap to protect static-sensitive components.
Step Action
1
Prepare the server for processor fan replacement as follows:
a. Shut down the server, and then disconnect the power and
peripheral device cables.
b. Place the server on its side.
c. Remove the side cover.
d. Remove the upper fan holder foam.
Nortel CallPilot
703t Server Maintenance and Diagnostics
NN44200-702 01.03 Standard
5.0 3 April 2007
Copyright © 2007, Nortel Networks Nortel Networks Confidential
.