Replacing the processor fan 99
For instructions, see"Preparing the server for hardware maintenance"
(page 81).
WARNING
Failure to follow the procedures in"Preparing the server for
hardware maintenance" (page 81) can result in electrical
shock or equipment damage.
2
Disconnect the fan power cable connector from the server’s
motherboard.
3
Use both hands to spread the fan bracket tabs apart, and then move
the fan away from the posts that hold it in place.
Tip: You may need to lift the bottom fan holder foam slightly to
create more space.
4
Lift the fan up and out of the server.
install processor fan
5
Use both hands to spread the fan bracket tabs apart.
Tip: You may need to lift the bottom fan holder foam slightly to
create more space.
Nortel CallPilot
703t Server Maintenance and Diagnostics
NN44200-702 01.03 Standard
5.0 3 April 2007