Replacing a rear system fan 95
Note: The fan closest to the top of the server connects to the
connector labeled sysfan5. The fan closest to the bottom of
the server connects to the connector that is labeled sysfan3.
8
Reinstall the add-in boards.
9
Reconnect any cables you disconnected to the add-in boards.
10
Ensure that any cables located near the fans are kept well away
from the fans.
CAUTION
If a cable is caught in a fan, the fan will break.
11
Replace the upper fan holder foam.
For instructions, see "To replace the upper fan holder foam" (page
88).
12
Replace the side cover of the server.
13
Reconnect all peripheral device cables and power cord.
14
Power up the server.
—End—
Replacing a rear system fan
Replace a malfunctioning fan with the same type as the one removed.
For more information about replacing a fan, contact your Nortel customer
service representative.
Note: The fan replacement kit contains four fans: two front fans and
two rear fans.
To remove a rear system fan
CAUTION
Use an ESD wrist strap to protect static-sensitive components.
Nortel CallPilot
703t Server Maintenance and Diagnostics
NN44200-702 01.03 Standard
5.0 3 April 2007