96 Chapter 8 Replacing basic chassis components
Step Action
1
Prepare the server for rear system fan replacement as follows:
a. Shut down the server, and then disconnect the power and
peripheral device cables.
b. Place the server on its side.
c. Remove the side cover.
For instructions, see"Preparing the server for hardware maintenance"
(page 81).
WARNING
Failure to follow the procedures in"Preparing the server for
hardware maintenance" (page 81) can result in electrical
shock or equipment damage.
2
Lift the tab on the bracket that holds the fan in place.
3
Angle the fan towards the interior of the server, and then lift it away
from its slot.
4
Disconnect the power cable of the fan connector from the server’s
motherboard.