124 Chapter 10 RAID operations
10
Press Ctr l+Alt+Delete to restart the server.
—End—
Configuring RAID using LSI Elite 1600 controller and Ctrl+M
The configuration of the RAID card is stored on both the card and on the
hard drive, so typically you are not required to reconfigure RAID unless you
are making a change to the RAID system (for example, if you replace the
hard drives with higher-capacity hard drives).
WARNING
Nortel strongly recommends that you not perform low level
formatting. Performing low level formatting results in the drives
becoming unusable.
CAUTION
This procedure requires that the logical drive be initialized. When
you initialize the logical drive, all data on the hard dr ives is erased.
Do not perform this procedure unless you are replacing the
hard drives, or you are rebuilding the CallPilot system (that is,
reinstalling the Windows operating system and CallPilot software).
To configure an LSI Elite 1600 RAID system
To configure RAID, do the following:
Step Action
1
Tur n on the server and press Ctrl+M when prompted during system
bootup.
Note: The Ctrl+M utility can take up to 1 minute to launch with
111U firmware. The system may appear frozen. Do not reset.
2
From the Management menu, select Objects and press Enter.
3
From the Objects menu select Adapter and press Enter.
4
From the Adapter menu select Factory Default.
5
Select Yes to confirm the selection and press Enter.
6
Press Ctrl+Alt+Delete when prompted to restart system.
7
During bootup, press Ctrl+M to re-enter the RAID setup utility.
Nortel CallPilot
703t Server Maintenance and Diagnostics
NN44200-702 01.03 Standard
5.0 3 April 2007
Copyright © 2007, Nortel Networks Nortel Networks Confidential
.