28 Chapter 3 Troubleshooting your CallPilot system
When the 703t server does not boot and there are no audible beeps
To check why server fans are not turning when server does not
boot
Step Action
1
Ensure that the power cord is properly connected into an electrical
outlet.
2
If the problem continues, ensure that there is power to the electrical
outlet.
—End—
To check why server does not boot with fans turning
Step Action
1 Ensure that the monitor is turned on.
2
If the problem continues, ensure that the internal power supply to the
boards is connected correctly.
—End—
When the 703t server does not boot and the system board LED is red
If the r ight-most status LED on the front of the 703t server is red, this is
usually due to failure of the Board Management Controller.
The most likely cause is changing boards without completely powering
down the 703t server and disconnecting the power cable.
To check why server does not boot and system board LED is red
Step Action
1
Shut down the 703t server
2
Disconnect the power cable.
3
Wait 1 minute.
4
Reconnect the power cable and attempt to restart the 703t server.
5
If the problem continues, contact your Nortel technical support
representative for assistance.