3.28 Power Status 1 (PWR_STAT1)
Address
Register Offset
PWR_STAT1 025h
Function
The PWR_STATn registers are used to monitor the status of individual power supplies. If a bit is set to '1', the respective power
supply is operating correctly.
Note that unassigned bits default to one, allowing power failure detection to be easily performed (if the value is not FFh, at least
one supply is not operating).
Due to the high variability of the hardware devices used, PWR_STATn register bits are not assigned any universally fixed values.
For more details, see the target platform documentation.
Diagram
Bits
7 6 5 4 3 2 1 0
R 0V85 2VX LVAUX SD_AVDD SD_VDD USB VDD
W
NONE 1 1 1 1 1 1 1 1
Fields
Field Function
7
0V85
VCC_0V85 Power Supply Status:
0= Power supply is disabled or faulted.
1= Power supply is operating.
6
2VX
2.1V and 2.5V Power Supply Status:
0= One or both power supplies are disabled or faulted.
1= Power supplies are operating.
5
LVAUX
LVAUX Power Supply Status:
0= Power supply is disabled or faulted.
1= Power supply is operating.
4
SD_AVDD
SD_AVDD Power Supply Status:
0= Power supply is disabled or faulted.
1= Power supply is operating.
3 SD_SVDD and SD_OVDD Power Supply Status:
Table continues on the next page...
NXP Semiconductors
Qixis Programming Model
QorIQ LX2160A Reference Design Board Reference Manual, Rev. 4, 07/2020
Reference Manual 79 / 116