EasyManua.ls Logo

Oce VarioStream 7000 SINGLE - Replacing corotrons; Important

Oce VarioStream 7000 SINGLE
384 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.3.4 Replacing corotrons
A29246-X20-X-4-7680 / fa702.fm 269
7.3.4 Replacing corotrons
The printer detects the end of the corotron's service life automatically and displays a
warning on the operator panel.
7.3.4.1 Preparing corotron replacement >>> page 270
Important
When replacing the corotrons, observe the following safety directives:
Corotrons can only be replaced when printing is stopped.
Corotrons may only be used for the purpose for which they were originally intended.
If the corotron had only a short service life, the cause of the problem must be
identified in order to prevent further damage.
When replacing a corotron, always wear the gloves provided.
Ensure that you do not touch or damage the corotron wires.
Expendable See section
Prepare corotron replacement 7.3.4.1 Preparing corotron replacement >>>
page 270
Replace transfer corotron 7.3.4.2 Replacing the transfer corotron
(1 cartridge) (pinfed) >>> page 271
Transfer corotron wire is torn
7.3.4.2 Replacing the transfer corotron
(1 cartridge) (pinfed) >>> page 271
Replace charge corotrons 7.3.4.4 Replacing charge corotrons (5
cartridges) >>> page 278
Charge corotron wire is torn 7.3.4.5 Replacing charge corotrons (torn wire)
>>> page 281
Replace discharge corotrons 7.3.4.6 Replacing discharge corotrons (2
cartridges) >>> page 284
Discharge corotron wire is torn 7.3.4.7 Replacing the discharge corotron (torn
wire) >>> page 287
Complete corotron replacement 7.3.4.8 Complete corotron replacement >>>
page 290

Table of Contents