6.5 Cleaning the fuser station
A29246-X20-X-4-7680 / fa603.fm 191
6.5 Cleaning the fuser station
Cleaning the fuser station
Caution
There can be a high build-up of static charge when vacuuming the toner spill.
Always use an industrial vacuum cleaner with a grounded suction tube, rubber
nozzle and filter set for fine dust. For larger quantities of toner spill (e. g. full bottle),
the industrial vacuum cleaner must be explosion-proof.
Proceed as follows:
1. If the printing system has not yet stopped, click the following button:
2. Open the front and side door of the fuser station.
Caution
The components in the fuser station reach a surface temperature of approximately
230
o
C in operation.
If you touch them, you may burn yourself.
Do not touch any parts behind the safety covers identified with the icon .
3. Turn the knob on the oiling unit to the
left.
4. Swivel on oiling unit.
1 of 8