Technical data
372 A29246-X20-X-4-7680 / faA01.fm
Environmental conditions
Operating ranges
Cooling and fresh air, air cleanliness
To maintain the thermal equilibrium for climatic class 3K2 (general office climate) in the
printing system location, a combination of sufficient cool and fresh air is required.
Dimensions and weight
Dimensions
Recommended
optimum
operating range
Limit of
operation
Limit value with High
Temperature Kit
(optional)
Temperature 18°C to 24°C 10°C to 32°C up to 35° C (95° F) max.
Relative humidity 38 % to 60 %
(Paper: 45 ± 7,5 %)
10% to 80 % up to 45% max.
Lowest absolute
humidity
2g/m
3
1g/m
3
-
Highest absolute
humidity
22 g/m
3
25 g/m
3
18 g/m
3
Simplex printing system
for 50 Hz power
frequency
Simplex printing system for
60 Hz power frequency
Cooling air
7,200 m
3
/h 8,300 m
3
/h
Fresh air 10% - 20% of the cooling air must be fresh air
Air
cleanliness
according to air cleanliness class 2
Height 1,549 mm (60.3 ")
Length 2,316 mm (90 ")
Depth 1,060 mm (37 ")