Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 5-3
Read Cycle
Read Cycle Serial Commands
Trigger Mode/Filter Duration
<K200,trigger mode,leading edge trigger filter,trailing edge
trigger filter>
Serial Trigger Character <K201,serial trigger character>
External Trigger State <K202,external trigger state>
End of Read Cycle <K220,end of read cycle mode,read cycle timeout>
Decodes Before Output <K221,good decode(s) needed>
Multisymbol <K222,number of symbols,multisymbol separator>
Start Trigger Character <K229,start character>
Stop Trigger Character <K230,stop character>
Capture Mode
<K241,capture mode,number of rapid captures,rapid capture
mode,number of continuous captures,images per read cycle
limit,read cycle history limit>
Capture Time
<K242,time before first capture,time between captures 1 and
2,timebetween captures 2 and 3,time between captures 3 and
4,time between captures 4 and 5,time between captures 5 and
6,time between captures 6 and 7,time between captures 7 and 8
Image Storage <K244,image storage type,image store mode>
Image Processing Timeout
<K245,image processing timeout>

Table of Contents