EasyManua.ls Logo

Omron V430-F Series - Output Filter Configuration

Omron V430-F Series
404 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 14-9
Output Format
Output Filter Configuration
Rules for Output Filter Configuration
Output Filter Configuration Rule # 1
Each symbol that is decoded must match one of the filters before it can be saved to a read
cycle record. There is an exception to this rule, however, when the number of symbols
required for a read cycle exceeds the number of active filters. In such a case, unfiltered
symbols can be placed into unfiltered output positions.
For example, if the number of symbols required is 6 but there are only 4 active filters, the
last 2 positions can be filled by any (unfiltered) qualified symbol.
Output Filter Configuration Rule # 2
The same filter setup can be used multiple times.
For example, filters 1, 2, and 3 can be set up to filter Data Matrix symbols, and the output
will occur in the order the symbols are decoded.
Output Filter Configuration Rule # 3
All qualified symbols will be sorted and output in the matching filter position. If a symbol
matches filter 3, it will be output as the third symbol. If a filter does not have a matching
qualified symbol, a No-Read message will be output in place of the symbol (assuming the
No-Read message is enabled).
For example, if there is not a symbol that meets filter 3’s requirements, then a No-Read
message will be output in the third output position.
Definition: Output filtering is a method of providing a set of good read qualifiers and also
providing ordered output. There is a filter for up to the first 10 positions in a
multisymbol output. The first filter corresponds to the first symbol output at the
end of the read cycle. Each filter has has settings for the following four
parameters:
Symbology
,
Symbol Length
,
Data
, and
Configuration Database
Number.
Serial Cmd: <K744,filter number,symbology,length,wildcard,placeholder,data,
unused,database index>

Table of Contents

Other manuals for Omron V430-F Series

Related product manuals