9-10 Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Sequence Step Interval
Sequence Step Interval
Example: If Sequence Step is set to 3 and Sequential Matching is set to Increment:
Usage: Useful in applications in which it is desirable to count by intervals other
than 1.
Definition: Sequencing in Matchcode operations can occur in steps from 1 to
32,768.
Sequencing performs like a mechanical counter by displaying positive
integers and a specific number of digits after roll-overs. For example, 000
– 3 = 997 (not -3) and 999 + 3 = 002 (not 1002).
Serial Cmd: <K228,sequence step interval
>
Default: 1
Options: Any number from 1 to 32768
Master Symbol Decoded Symbol Master Symbol after Decode
003 001 003
003 002 003
003 003 006
006 004 006
006 005 006
006 006 009