Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 3-17
Communications
Postamble
Postamble Status
Postamble Characters
Usage: Useful for identifying and controlling incoming data. For example, defining
the postamble as a carriage return and a line feed causes each decoded
message to be displayed on its own line.
Definition: Allows the user to enable or disable up to four postamble characters that
can be added to the end of the decoded data.
Serial Cmd: <K142,status,postamble character(s)>
Default: Enabled
Options: 0 = Disabled 1 = Enabled (within any protocol)
Serial Cmd: <K142,status,postamble character(s)>
Default: ^M^J corresponds to: carriage return/line feed.
Options: To enter control characters within a serial command, hold down the control
key while typing the desired character.
Example: <K142,1,CNTL-m CNTL-j> to enter ^M^J.