Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 7-9
I/O Parameters
No-Read Message
No-Read Message Mode
Disabled
Only symbol data is output after a read cycle.
Enabled
When the reader is in a triggered mode, a No-Read message will be appended for each
failed read attempt.
No-Read Message
Note: No-Read Message will only be transmitted if Symbol Data Output is set to Match,
Mismatch, or Good Read.
No-Read Message can be set to any ASCII character.
Usage: Used in applications where the host needs serial verification that a symbol
has not been read and especially useful in new print verification.
Definition: When enabled, and if no symbol has been decoded before timeout or the
end of the read cycle, the No-Read message will be transmitted to the host.
Serial Cmd: <K714,No-Read message status,No-Read message>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: Any combination of ASCII characters can be defined as the No-Read
message.
Serial Cmd: <K714,No-Read message status,No-Read message>
Default: NOREAD
Options: A string of up to 64 characters.