5-12 Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Serial Trigger
Serial Trigger
Serial Trigger Character (Delimited)
Note: Serial Data or Serial Data or External Edge triggering mode must be enabled for
Serial Trigger Character to take effect.
Usage: Allows the user to define the trigger character and delimiters that start
and stop the read cycle.
Definition: A serial trigger is considered an online host command and requires the
same command format as all host commands. It must be entered within
angle bracket delimiters < > or, in the case of non-delimited triggers, it must
define individual start and stop characters.
Usage: Allows the user to define the trigger character that initiates the read cycle.
Definition: A single ASCII host serial trigger character that initiates the read cycle.
A delimited trigger character is one that either starts or ends the read cycle
and is enclosed by delimiters such as < >.
Serial Cmd: <K201,serial trigger character>
Default: Space bar
Options: Any single ASCII character, including control characters, except NUL (0x00
in hex), an existing host command character, or an on-line protocol character.
Control characters entered on the command line are displayed in the menu
as mnemonic characters.