Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 8-5
Symbol Quality
Symbol Quality Separator/Output Mode
Symbol Quality Separator applies to both Symbol Quality groups: ISO/IEC 16022 Symbol
Quality Output, ISO/IEC 15415 Symbol Quality Output, ISO/IEC 15416 Symbol Quality Out-
put, ISO/IEC 29158 Symbol Quality Output, and Microscan Symbol Quality Output.
Symbol Quality Separator
Symbol Quality Separator by ESP
Definition:
Inserts a separator between each enabled field of the symbol quality output.
Serial Cmd: <K708,symbol quality separator,output mode>
Default: <SP> (space character)
Options: Any ASCII character.
When you double-click on the
default separator SP, the Symbol
Quality Separator Calculator
appears. Use the calculator keypad
for one-click separator configuration.